1
FUNCTIONS
This chapter describes the functions of the D/A converter module and the setting methods for those functions. For details on
the I/O signals and the buffer memory, refer to the following.
Page 135 I/O Signals
Page 146 Buffer Memory Areas
• This chapter describes I/O signals and buffer memory addresses for CH1. For details on the I/O signals and
buffer memory addresses for CH2 and later, refer to the following.
Page 135 List of I/O signals
Page 146 List of buffer memory areas
• in error codes and alarm codes indicates a channel where an error or alarm has occurred. A numerical
value corresponding to the error comes in . For details on the numerical values, refer to the following.
Page 128 List of Error Codes
Page 132 List of Alarm Codes
1.1
Modes
The D/A converter module has the high-speed output mode, normal output mode, wave output mode, inter-module
synchronization mode, and offset/gain setting mode. Change the operation mode according to the function used.
High-speed output mode
This operation mode is for performing the high-speed D/A conversion. The value set in 'CH1 Digital value' (Un\G460) is output
in analog after the D/A conversion. Conversion speed is 1s/CH.
Program
CH
Normal output mode
This operation mode is for performing the normal D/A conversion. The value set in 'CH1 Digital value' (Un\G460) is output in
analog after the D/A conversion. Conversion speed is 10s/CH.
Program
CH
1 FUNCTIONS
16
1.1 Modes
Digital value
D/A conversion
Digital value
Shift function
Scaling function
D/A conversion
Analog output
HOLD/CLEAR
function
Warning output
Check code result
function
Analog output
HOLD/CLEAR
function
Analog output
Rate control
function
Analog output