Sharpening and Balancing Blades

!
WARNING!
Protect your hands with gloves
when working with the blades.
1.
Remove the blades as described in the
previous section.
2.
Fix the blade in a vice and sharpen it with
a sharpening file.
3.
Balance the blade by:
Attaching a punch, e.g. horizontally in the
vice as shown.
Thread the hole in the centre of the blade
over the punch and make sure that the
blade is equally weighted. The illustration
shows a blade that needs to be adjusted,
it must be filed more so as to attain the
right balance (at the arrow).
Fit in the reverse order.
!
WARNING!
If the blades are cracked, whether
caused by poor repair or other
damage, they could break while
being used. The risk increases if
the blades are poorly balanced.

Removing the BioClip plug (Combi)

To change a Combi unit from the BioClip
function to a cutting unit with rear ejection,
remove the BioClip plug, which is located
under the unit, attached with three screws.
1.
Put the cutting unit in the service
position, see "The Cutting Unit's Service
Position ProFlex" on page 97. and page
89 for Pro 18:
2.
Remove the three screws holding the
BioClip plug, and remove the plug.
3.
Tip: Fit three full-thread screws M8x15
mm in the screw holes to protect the
threads.
4.
Return the unit to the normal position.
Fit the BioClip plug in the reverse order.
REPAIR INSTRUCTIONS
Sharpening blades
Balancing blades
Removing the BioClip plug