Sharpening And Balancing The Blades; Dismantling The Bioclip Plug - Husqvarna PT26D Workshop Manual

Hide thumbs Also See for PT26D:
Table of Contents

Advertisement

An oil filter wrench, for example, can be used
to hold the pulley in place when the screw is
tightened.
Sharpening and balancing
the blades
.
WARNING!
Protect your hands with gloves
when working with the blades.
Remove the blades as described in the
previous section.
Carefully clean the blades and check for
cracks. Crack indicating fluid is an good tool.
If signs of cracking are discovered the blades
should be discarded.
Fix the blade in a vice and sharpen it with a
sharpening file.
Attaching a punch, for example, horizontally
in the vice as shown.
Thread the hole in the centre of the blade
over the punch and make sure that the blade
is equally weighted. The illustration shows a
blade that needs to be adjusted, it must be
filed more so as to attain the right balance (at
the arrow).

Dismantling the BioClip plug

To change a Combi unit from the BioClip
function to a cutting unit with rear ejection,
remove the BioClip plug, which is located
under the unit.
1.
Put the unit in the service position.
2.
Remove the screws holding the BioClip
plug, and remove the plug.
Tip: Fit full-thread screws
M8x15 mm in the screw holes to protect
the threads.
3.
Return the unit to the normal position.
Fit the BioClip plug in the reverse order.
REPAIR INSTRUCTIONS
Counterhold
Sharpening blades
Balancing blades
Dismantling the BioClip plug
8043-181
8043-026
8043-027
8009-289
97