Reparation instructions

Grinding and balancing of blades

WARNING!
When working with the blades,
use protective gloves.
1. Remove the blades according to the
decription in the previous section.
2. Clamp the blade in a screw vice and file it so
that it becomes sharp.
3. Balance the blade as follows:
• Fix, for example, a mandrel horizontally in a
screw vice according to the diagram.
• Push the blade onto the mandrel via the hole in
the centre of the blade and check that the blade
balances evenly. The diagram shows a blade
which needs to be adjusted, it must be ground
further to obtain the correct balance (at the
arrow).
• Installation is carried out in the reverse remo-
ving order.
WARNING!
If the blades are cracked,
whether caused by poor repair
or other damage, they could
break while being used. The risk
increases if the blades are
poorly balanced.
Removing the BioClip plug (Combi)
To change a Combi unit from the BioClip function
to a cutting unit with rear ejection, remove the
BioClip plug, which is located under the unit,
attached with three screws.
1. Put the unit in service position.
2. Combi 103, 112
Remove the three screws holding the BioClip
plug, and remove the plug.
3. Combi 103, 112
Tip: Fit three full-thread screws M8 x 15 mm
in the screw holes to protect the threads.
4. Combi 94
Remove the wing nut and BioClip-plug.
5. Return the unit to the normal position.
Fit the BioClip plug in the reverse order.