T10FH

4.6 Installing the stator

On delivery, the stator has already been fitted ready for operation. The an
tenna segments have to be separated for installation. To stop you modifying
the center alignment of the segment rings opposite the base of the stator, we
recommend that you separate only one antenna segment from the stator. De
pending on the operating conditions, it may be necessary to stabilize the an
tenna ring with a clamp fixture (included among the components supplied).
See page 23.
Fig. 4.6: Screw fittings of the antenna segments
1. Slacken and remove the screw fittings (M5) on one antenna segment.
Make sure that the fantype lock washers are not lost.
2. Place the antenna segments around the transmitter on the rotor and close
the antenna ring again. Make sure that all the fan−type lock washers in
front of and behind the antenna segment are present. If necessary, fit the
clamp fixture at the same time (see page 23).
3. Use an appropriate base plate to install the stator housing in the shaft train
so that there is sufficient possibility for horizontal and vertical adjustments.
Do not yet fully tighten the screws.
A2037−4.0 en
Fan type lock washers
Fan type lock washers