Specifications - HBM T10FH Mounting Instructions

Torque flange
Hide thumbs Also See for T10FH:
Table of Contents

Advertisement

T10FH
11

Specifications

Type
Accuracy class
Torque measuring system
Nominal (rated) torque M
for reference only
Nominal (rated) sensitivity (range
between torque = zero and nominal
(rated) torque)
Frequency output
Voltage output
Sensitivity tolerance (deviation of
the actual output value at M
nominal (rated) sensitivity)
Frequency output
in conjunction with HBM test report
in conjunction with PTB calibration
certificate per DIN 51309 or
EA 10/14
Voltage output
in conjunction with HBM test report
in conjunction with PTB calibration
certificate per DIN 51309 or
EA 10/14
Output signal at torque = zero
Frequency output
Voltage output
Nominal (rated) output signal
Frequency output
with positive nominal (rated) torque
with negative nominal (rated)
torque
Voltage output
with positive nominal (rated) torque
with negative nominal (rated)
torque
Load resistance
Frequency output
Voltage output
Long term drift over 48 h
Voltage output
Measurement frequency range
Voltage output
Group delay time
Frequency output
Voltage output
1)
RS 422 complementary signals; factory settings
A2037−4.0 en
T10FH (rotating); option 2, code L
kN⋅m
100
nom
kft lb
73.8
kHz
V
of
nom
%
%
%
%
kHz
V
kHz
15 ("5 V symmetric)
kHz
V
V
mV
Hz
ms
ms
0.1
130
150
95.9
110.6
5
"10
"0.25
"0.1
"0.35
"0.2
10
0
1)
/ 15 (12 V asymmetric)
1)
5 ("5 V symmetric)
/ 5 (12 V asymmetric)
+10
−10
> 2
> 5
"3
0 ... 1000 (−3 dB)
0.15
0.9
41
200
250
300
147.5
184.4
221.3
"0.4
"0.1
"0.5
"0.2
HBM

Advertisement

Table of Contents
loading