44
Type
Accuracy class
Torque measuring system
Nominal (rated) torque M
for reference only
Nominal (rated) sensitivity at
M
nom
(nominal (rated) signal range bet
ween torque= zero and nominal
(rated) torque)
Sensitivity tolerance (deviation
of the actual output value at M
of nominal (rated) sensitivity)
in conjunction with HBM test re
port
in conjunction with PTB calibra
tion certificate per DIN 51309 or
EA 10/14
Temperature influence per 10 K
in the nominal temperature
range
on the output signal, related to
the actual value of signal span
on the zero signal, related to the
nom. sensitivity
Linearity deviation including
hysteresis,
related to the nominal (rated) sen
sitivity
Rel. standard deviation of the
reproducibility, per DIN 1319,
relative to variation of the output
signal
Input resistance at reference
temperature
Output resistance at reference
temperature
Reference excitation voltage
Operating range of the excita
tion voltage
Transducer identification
HBM
T10FH (non rotating); option 2, code N
kN⋅m
100
nom
kft lb
73.8
mV/V 1.1 ... 1.9 (The sensitivity is specified on the identifi
nom
%
%
%
%
%
%
W
W
V
V
0.1
130
150
200
95.9
110.6
147.5
cation plate)
"0.25
"0.1
"0.1
"0.05
"0.1
"0.02
1550"100
1300 ... 1500
5
2.5 ... 12
TEDS per IEEE 1451.4
T10FH
250
300
184.4
221.3
"0.4
"0.1
A2037−4.0 en