HBM T10FH Mounting Instructions page 46

Torque flange
Hide thumbs Also See for T10FH:
Table of Contents

Advertisement

46
Nominal (rated) torque M
for reference only
4)
Load limits
Limit torque
Breaking torque
Axial limit force
Lateral force limit
Bending limit moment
Oscillation bandwidth per
DIN 50100 (peak to peak)
upper maximum torque
lower maximum torque
4)
Each type of irregular stress can only be permitted with its given static load limit (bending moment, lateral or
axial load, exceeding the nominal (rated) torque) if none of the others can occur. Otherwise the limit values
must be reduced. If for instance 30 % of the bending limit moment and also 30 % of the lateral limit force
are present, only 40 % of the axial limit force are permitted, provided that the nominal (rated) torque is not
exceeded. With the permitted bending moments, axial, and lateral limit forces, measuring errors of about
1 % of the nominal (rated) torque can occur. If the nominal (rated) torque is exceeded, ensure that the
maximum modulation range of the signal output electronics is being observed.
HBM
kN⋅m
100
nom
kft lb
73.8
kN⋅m
kN⋅m
kN
kN
kN⋅m
kN⋅m
kN⋅m
kN⋅m
130
150
200
95.9
110.6
147.5
200
> 300
230
110
22
200
+150
−150
T10FH
250
300
184.4
221.3
400
> 600
290
240
35
400
+300
−300