Chapter 4 REGISTRATION MARK SETTINGS AND DETECTION
To perform manual axis adjustment using a pre-printed frame or other marks on the medium as reference points,
press the [F2] key (AXIS).
To perform automatic or manual detection of the registration marks, press the [F4] key (MARKS).
When the displayed setting is satisfactory, press the [ENTER] key to confirm your selection.
(5) When the [F2] key (AXIS) or [F4] key (MARKS) is pressed, the axis adjustment menu is displayed.
FORCE
2 POINT
SPEED
Press the [F2], [F3] or [F4] key to display the black dot next to your desired mode and then press the [ENTER] key
to confirm your selection. If AXIS was selected for the registration mark mode the plotter returns to Ready status.
(6) If MARKS was selected for the registration mark mode, the MARK MOVE No. menu is displayed.
FORCE
MARK MOVE No.
SPEED
By specifying the distance between registration marks and not performing scanning in the areas where there are no
registration marks, this function enables a reduction in the time required to read registration marks and also prevents
the misreading of dirt or other foreign matter on the medium as a registration mark. Up to three settings can be
registered.
(7) Use the [
] or [
and then press the [ENTER] key.
FORCE
MARK MOVE No.
SPEED
(8) Next, the MARK MOVE DIST. menu is displayed.
FORCE
MARK MOVE DIST.
X=0000mm
SPEED
Use the [
] or [
the [ENTER] key to confirm your selections.
Registration mark pattern 1
Specify [Y]
Specify [X]
If there is no need to skip reading between registration marks, specify X = 0, Y = 0 (the default values). If 0 mm is
specified for the spacing, the plotter will not skip reading between registration marks. It will continue searching until
the next registration mark is found.
If 2-point reading has been selected, the Y numeric value is disregarded.
4-4
OFFSET
3 POINT
4 POINT•
QUALITY
OFFSET
No.=1
QUALITY
] key to move through the selections "1", "2," and "3". Select the number that you wish to register
OFFSET
No.=1
QUALITY
OFFSET
Y=0000mm
QUALITY
] key to move the blinking cursor, and the [
Registration mark pattern 2
Specify [Y]
] or [
Specify [X]
] key to change the numeric value. Press
Registration mark pattern 3
Specify [Y]
Specify [X]