GRAPHTEC CUTTING PRO FC2250 Series User Manual page 115

Table of Contents

Advertisement

Chapter 6 TROUBLESHOOTING
HP-GL™ Command Mode Error Messages
Error message
ERROR 1 Instruction
not recognized
ERROR 2 Wrong number
of parameters
ERROR 3 Out of range
parameters
ERROR 5 Unknown
character set
ERROR 6
Position overflow
ERROR 7
Buffer overflow
ERROR 10 Invalid
I/O output request
ERROR 11 Invalid
byte following ESC.
ERROR 12 Invalid
byte in I/O Control
ERROR 13 Out of
range I/O parameter
ERROR 14 Too many
I/O parameters
ERROR 15 Error in
I/O transmission
ERROR 16 I/O buffer
overflow
6-6
Cause
An unrecognizable instruction was executed.
Noise was input to the plotter upon execution
of the software application.
The software's output settings have been
changed.
The plotter's interface settings have been
changed.
A command was executed with the wrong
number of parameters.
A command containing an unusable
parameter was specified.
An unrecognizable character set was
specified.
A command was executed with coordinate
data that exceeds the effective cutting/
plotting area.
The data being input exceeded the capacity
of the plotter's downloadable character
buffer, polygon buffer, etc.
During execution of an output command,
another output command was executed.
The ESC character was followed by an
invalid byte.
A device control command containing an
invalid byte was received.
A parameter outside of the permissible
numeric range was specified.
Too many interface-related command
parameters were received.
A framing error, parity error or overrun error
occurred.
The interface buffer overflowed.
Solution
Execute a recognizable command.
Press the [ENTER] key.
Configure the software for output by this
plotter.
Ensure that the software's interface settings
are correctly set.
Ensure that the plotter's interface settings
are correctly set.
Execute the command with the correct
number of parameters.
Execute the command with its parameters
specified within their permissible ranges.
Specify a recognizable character set.
Execute the command with its coordinate
data specified within the effective cutting/
plotting area.
Increase the buffer size.
Check the program.
Check the program.
Check the program.
Check the program.
Check the program.
Change the RS-232C transmission
conditions.
Change the RS-232C transmission
conditions.

Advertisement

Table of Contents
loading

Table of Contents