Replacing Flash Modules - Oracle Sun Netra X4270 Service Manual

Table of Contents

Advertisement

11.
If you replaced faulty DIMMs, clear the server DIMM faults.
a.
To see server faults, log in to the ILOM SP as root and type the following
ILOM CLI command list all known fault on the system:
->
The server lists all known faults, for example:
-> show /SP/faultmgmt
b.
To clear the fault, type the following command:
->
Where Pn is the DIMM number. For example, to clear a fault on the DIMM in location D2
on CPU0:
-> set /SYS/MB/P0/D2 clear_fault_action=true
Are you sure you want to clear /SYS/MB/P0 (y/n)? y
Set ???clear_fault_action" to ???true???
Related Information
"DIMM and CPU Physical Layout" on page 133
"DIMM Population Rules" on page 134
"DIMM Considerations and Limitations" on page 135
"DIMM Rank Classification Labels" on page 136
"Error Correction and Parity" on page 136
"Identify and Remove Faulty DIMMs" on page 137

Replacing Flash Modules

The server contains two slots for flash modules. These topics describe how to remove and
install these flash modules.
show /SP/faultmgmt
Targets:
0 (/SYS/MB/P0/D2)
Properties:
Commands:
cd
show
n
set /SYS/MB/P
clear_fault_action=true