Oracle Sun Netra X4270 Service Manual page 131

Table of Contents

Advertisement

3.
Lower the duct to the horizontal position until the tab secures in place.
Ensure that the LED board cable is securely connected to the PCI mezzanine and is routed
beneath the air duct.
4.
Reconnect the fan tray 0 power cable to the PCI Mezzanine.
Route cable through the retention clips on top of the air duct.
5.
Replace any full-length, full-height PCIe2 cards to the PCI mezzanine.
Reconnect any internal cables connected to these PCIe2 cards. See
Slots 4 and 5" on page
6.
Consider your next step:
If you installed the air duct as part of another procedure, return to that procedure.
Otherwise, continue with this task.
7.
Install the PCI mezzanine.
See
"Install the PCI Mezzanine" on page
8.
Return the server to operation.
See
"Returning Server to Operation" on page
117.