Temporary operation of lift
7

Temporary operation of lift

When the lift is installed, it is sometimes necessary to operate the lift functions in order to change the position of
the cylinders and the lift arms. To do this, the lift control card can be connected temporarily to run the functions.
To access the lift's control card, see section "8 Hydraulic unit and control card" on page 38.
NOTE.
The battery charger must not be connected when operating the lift. Risk of damage.
7.1

Connection

1. Connect a suitable control device to the control card, see illustration below. The number of available func-
tions varies depending on the lift model.
2. Connect an earth connection (GND) and +12/24V to the lift, see Image 52. See also section "18.2 Maximum
power consumption - Minimum recommended conductor cross sectional area" on page 76.
3. Insert a jumper between CSPWR and CS to simulate a cabin switch CS in the ON position, see illustration
below.
7.2

Operation

Use the control device to run the lift functions.
m
WARNING!
Take great care when running the lift functions and make sure nothing is trapped. There is a risk of injury
and damage.
7.3

Disconnection

1. Remove the jumper between CSPWR and CS.
2. Disconnect +12-24 V from the platform.
3. Disconnect the earth connection from the platform.
4. Disconnect the control device from the control card.
Control voltage
www.zepro.com
Outputs
Up
B
Down
E
Ctrl 1
Tilt
C
2H1
B
E
Ctrl 2
C
2H2
Ctrl 6
B
E
Ctrl 3
Radio
C
Lock
Ctrl 5
B
E
Ctrl 4
Spiral
C
Lock
Image 64. Temporary connection of lift control card
+12/24V
Image 63. The lift's cables for power supply
+
Sensor Power
IN OUT
PA-
PA+
CSPWR
Jumper
CS
Di 6
Di 5
Di 4
Di 3
Di 2
Di 1
Ai 1
Ai 2
Z 2500-130/150
+
GND
37