Functional description Z 2500 MA
11

Functional description Z 2500 MA

11.1

Sensor

Name
Ai 1
Ai 2
B
E
C
2H
Di1
Di2
Di3
Di4
Di5
Di6
Cs
2H
See also the electrical
www.zepro.com
Position
Function
(standard)
Controller
Up button
Controller
Down button
Controller
Tilt button
Controller
Two-hand but-
ton
Angle sensor
Tilting cylinder
Open platform
alarm
Cab
Activation
Controller
Two-hand but-
ton
diagram: "9.2 Z2500-130/150 MA" on page 42.
Description
Not used in this configuration
Not used in this configuration
Used in combination with B and E for tilt up and tilt down
Activated in connection with opening and closing of vehicle
body. Used for quick opening.
Not used in this configuration
Not used in this configuration
Non-actuated Di3 disables Tilt up with the secondary control
device so that the operator must use the two-hand button
- 2H together with the primary control device in order to
continue to maintain the tilt up function.
Pressure switch for falling pressure connected to +side of
tilting cylinder. In its actuated state, returns the connection
signal (+) to Di4, resulting in output signal (-) at Pa-. At the
same time (+) signal is sent on Pa+. 60 Bar (NC).
Not used in this configuration
Not used in this configuration
No signal in at Cs results in blocked control device terminals.
Signal to Cs usually comes from the cab switch. In individual
cases, where the cab switch is not used, the (+) signal
coming in to Cs is jumpered from (CS PWR) on nearby
terminal.
Activated in connection with opening and closing of vehicle
body. Used for quick opening.