Accessing The Hydraulic Unit And Control Card - Zepro Z 2500-130 Series Installation Instructions Manual

Tail lift
Table of Contents

Advertisement

Hydraulic unit and control card
8.1

Accessing the hydraulic unit and control card

To access the control card, see point 1 - 2. To access the hydraulic unit, see point 1 - 4.
1. Remove the protective cap, which is secured with a quick-release lock, see Image 66.
2. Move the release latch (A) to the left and then fold out the control card (B), see Image 67.
3. Remove the cabling from the control card for the hydraulic unit by the connector on the hydraulic unit, see
Image 68.
4. Release the hydraulic unit by unscrewing the wing nut and corresponding screw (C), see Image 69 and pull
out the hydraulic unit until the tank cap can be accessed, see "Image 65 on page 38.
Reinstall in reverse order.
m
WARNING!
Ensure that no cables are trapped or in any other way damaged when the control card is folded out or
removed.
Do not pull out the hydraulic unit more than necessary; make sure it is not pulled completely out of the
frame, as this can entail a risk of personal injury and damage to the equipment.
Image 66. Remove the protective cap
Image 68. Connection socket
www.zepro.com
A
Image 67. Release latch control card
C
Image 69. Releasing hydraulic unit
Z 2500-130/150
B
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents