Before installation
3.8

Temporary connection

When the tail lift is installed, it is sometimes necessary to operate its functions in order to change the position
of the cylinders and the lift arms. Temporarily connect the lift to enable the lift functions.
1. Connect a suitable control device to Ctrl 1/C1, see section 3.8.2/3.8.3.
2. Connect the tail lift's main power cable to battery +12/24V.
3. Connect the negative battery terminal to the tail lift's earth cable (GND).
4. Relay card TLC-B1: When operating, connect a cable (jumper) between an available power supply con-
nection (+) and CS on the relay card to simulate switch CS being on. Remove the cable immediately after
completed operation.
Control card ZePRO1: When operating, connect the cable (jumper) between the CSPWR and CS on the
control card to simulate that the CS switch is turned on. Remove the jumper immediately after completed
operation.
m
WARNING!
Take great care while running the lift functions and make sure nothing gets pinched: risk of personal
injury and material damage.
WL1 U7 U6 U5 U5 U4 U4 U3 U2 U1 U0
C1+
C1
C1+
Down
Up
2H
Tilt
Out
In
C2+
Down
Up
Tilt
C3+
Down
Up
TLC-B1
3.8.1
Battery maintenance
When installing the lift, when the lift is operated repeatedly, the battery charger must be used between opera-
tions to maintain the battery charge level.
!
IMPORTANT
The battery charger must not be connected when operating the lift. Risk of material damage.
16
Jumper
+
+
U3
U2
U1
+
U0
+
PA-
PA+
CS
WL2
CS+
S5+
S5
S4+
S4
S3+
S3
S2+
S2
S1+
S1
Image 17. Temporary connection
Outputs
B
Ctrl 1
E
Ctrl 1
C
2H1
B
E
Ctrl 2
C
2H2
Ctrl 6
B
E
Ctrl 3
Radio
C
Lock
Ctrl 5
B
E
Ctrl 4
Spiral
C
Lock
ZePRO1
ZN 2500-130/150
+
Sensor Power
IN OUT
PA-
PA+
Jumper
CSPWR
CS
Di 6
Di 5
Di 4
Di 3
Di 2
Di 1
Ai 2
Ai 1