To set EQTools to communicate with a particular programmer, simply click the radio button
•
next to the desired programmer in the list and then click <OK>
EQTools will now be set up to communicate with the attached programmer at the specified
•
address.
3.6.3 Resolving Programmer Detection issues
If no programmers are detected, please check the following:
The serial cable is connected between the PC COM port and the programmer or the RS485
•
Converter.
All programmers are powered up.
•
All programmers have a unique 'Node Address'.
•
The 'RS485 Converter' (if used) is powered on.
•
If multiple programmers are detected but some are not detected, please check the following:
The RS485 cable is connected between the last detected programmer and the first non-
•
detected programmer.
Try swapping the RS485 cable for a known working cable just in case the cable is faulty.
•
Make sure each programmer has a unique 'Node Address'. If more than one programmer
•
has the same address then this may cause 'Communications Errors'.