1.2 Rear Panel IDC Connector Ports and signal routing

The 'ISPnano Series 3 ATE' programmer features three 'IDC Ports' on the back of the programmer
as detailed in the illustration below.
(1) TARGET
ISP PORT
(3) REMOTE
CONTROL
PORT
The purpose of each connector is described in the table below.
Connector
name
(1) 'Target ISP Port'
(2) 'ATE ISP Port'
(3) 'Remote Control
Port'
Instructions:
Connect the 'Target System' (UUT) to the 16-way 'Target ISP Port'.
Connect the external 'ATE System' or other control system to the 'ATE ISP Port'.
If you plan to remote control the programmer, connect the relevant remote control signals to
the 'Remote Control Port'.
The signal routing depends on whether the relays are energised (ON) or de-energised (OFF) – see
table below.
Relay
Relays
position
ON
Indicator
OFF
OFF
(default)
ON
ON
100
Description
This port connects to the Target Device (UUT) on the Target
System.
This port connects to the external 'ATE System' or any other
control electronics which requires to be normally connected
to the Target Device on the Target System (UUT).
This port is used to remotely control the programmer from an
external ATE / ICT or PLC.
Signal routing
'Target ISP Port' signals are routed to the 'ATE ISP Port'
'Target ISP Port' signals are routed to the 'Internal Programmer Power
and I/O Driver Circuitry'
ISPnano Series Programmer - User Manual – V1.11 – 12
(2) ATE ISP
PORT
Connector
type
16-way IDC
14-way IDC
14-way IDC