Controlling The Relay Switching; Overview; Controlling The Relays From Eds (Development Mode) - Equinox Systems ISPnano I Series User Manual

Programmer
Table of Contents

Advertisement

Distributor of Equinox Technologies: Excellent Integrated System Limited
Datasheet of ISPNANO S3 KIT - ISP PORTABLE PROGRAMMER
Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com

4.0 Controlling the RELAY switching

4.1 Overview

The programmer controls the +12V supply to the relay coils by enabling the electronic 'EXT-VCC'
switch inside the programmer. This switch applies the voltage from the 'EXT-VCC' input (+12V) to the
relay coils. This causes the relays to switch so that the internal programmer I/O and power signals are
now connected to the Target System (UUT).

4.2 Controlling the RELAYs from EDS (Development Mode)

The simplest way to familiarise yourself with the operation of the RELAY switching is to make an
'EDS (Development)' project.
Instructions:
Launch EQTools
Select "Create a new EDS (Development Project)"
Select the programmer 'ISPnano Series III'
Go through the EDS Wizard and select <Save> at the end of the wizard to save the project.
The EDS project will now launch.
Click on the <Target Power Supply> tab
displayed.
1
The functions of the different sections of this screen are outlined in the table below.
a screen similar to the screenshot below is
2
3

Advertisement

Table of Contents
loading

Table of Contents