Table 6·4. CD ROM Drive Configuration Jumper Functions
Jumper
Label
Function
IDl,ID2,ID4
SCSI ID Address; Jumper IDI is least significant bit. Shipped
with address 2 set (default); jumper only on ID2
PRTY
Parity checking; Out
=
Disabled,
In
=
Enabled.
PRV/ALW
Media removal; Out
=
eject button enabled,
In
=
eject button ignored.
TEST
Test; for factory use only.
TERM
Termination power source; In
=
from drive,
Out
=
from bus
SCSI Bus Address Jumpers
Your CD ROM drive's SCSI ID jumpers must be set to the bus address it will
use. Your CD ROM has bus address 2 factory set. Set your CD ROM's SCSI
ID configuration jumpers for SCSI bus address you will use in the range of 0
through 6. Refer to Table 6-5 for bus address settings
Table 6·5. CD ROM SCSI
10
Addresses and Switch Settings
SCSI
Address IDl ID2 ID4
0
0
0
0
1
1
0
0
2
0
1
0
3
1
1
0
4
0
0
1
5
1
0
1
6
0
1
1
7
1
1
1