Monitor Spectrum

Displays the frequency-domain spectrum of the receive channel or band
for the selected device (mobile or base station). This allows you to a
quickly check that there is a signal that can be measured.
:CONFigure:MON
:FETCh:MON [n]?
:READ:MON [n]?
:MEASure:MON [n]?
The numeric parameter [n] can be omitted altogether, or if used, it must
NOTE
be equal to 1. The same measurement is performed in either case.
Front Panel
Access:
Table 7-1
n
Not specified or
n=1

Error Vector Magnitude (EVM)

Displays the I/Q Measured Polar Vector of the received signal, and lists
both the maximum and the average values for EVM (rms), EVM (peak),
Mag Error (rms), Mag Error (peak), Phase Error (rms), Phase Error
(peak), Frequency Error, I/Q Offset and the Droop Error.
:CONFigure:EVM
:FETCh:EVM [n]?
:READ:EVM [n]?
:MEASure:EVM [n]?
Front Panel
Access:
116
Measure
Results Returned
Results Returned
Returns the RF Envelope Trace (data array). This trace contains 401
data points.