Making Modulation Analysis Measurements
Interpreting Measurement Results
4. Peak deviation of the amplitude modulating signal is easily
determined from
time graph. There are about 7 divisions of peak-to-peak amplitude
modulation at 3% per division, yielding 10.5% peak amplitude. This
approximates the actual 10% of amplitude modulation applied to
create this signal.
Figure 4-32
Zoomed Magnitude Error Display Showing AM Interference
52
Figure
4-32, the zoomed magnitude error versus
Chapter 4