Schneeberger MONORAIL Series Mounting Instructions page 47

Profiled linear guideways and integrated measuring systems
Table of Contents

Advertisement

7
 Completing installation
Fig.89
Rail butt joint
Band joint
Fig.90
Gap max. 0.04 mm
Gap max.
0.2 mm
Fig.91
Installation
Multi-part strips should be installed according to the same process used in the case
of one-part strips (see „Installation procedure for one-piece strips" on page 43).
Follow the numbering of the strips. As with multi-part guide rails, the individual strip
components are provided with a butt joint number on their underside in the joint area.
1.
Install the first strip section.
2.
Install all further strips so that they are seamless at each joint
(gap size < 0.2 mm).
Alignment
Cover strips and guide rails are not the same length in the case of multi-part guide
rails. Always install strip and guide rail joints offset by approx. 70 mm.
Completing installation of one-part and multi-part strips
1.
Check that the strips have been positioned correctly and consistently and are
flush with the guide rail/s:
The cover strip has a slight upward curvature, with its edges touching the guide
rail surface.
The permissible gap size between guide rail and cover strip is 0.04 mm.
Strip height including curvature is max. 0.6 mm.
Height difference between cover strips at butt joints is max. 0.03 mm.