Installing Product Versions Ams 3B, Ams 4B, And Amsa 3L; Installing Product Version Amsabs - Schneeberger MONORAIL Series Mounting Instructions

Profiled linear guideways and integrated measuring systems
Table of Contents

Advertisement

6
 Installation
Fig.31
Fig.32
Fig.33
24
6.5.3 Installing product versions AMS 3B, AMS 4B, and AMSA 3L
1.
Where necessary, remove the cover plate from the housing.
2.
Carefully insert the read head into the lateral recess of the housing.
3.
Insert and tighten the fastening screws. No additional adjustment is necessary.
The tightening sequence is irrelevant in this case.
6.5.4 Installing product version AMSABS
1.
Where necessary, remove the cover plate from the housing.
2.
Activate the battery (see „5.7 Preparing the measuring system for installation" on
page 16).
3.
Carefully insert the read head into the recess in the housing using a rotating
motion.
4.
Swivel the distance reference cover plate (1) for mounting.
5.
Slide the read head (2) towards the carriage until it stops and hold it down
(see Figure). This ensures that the measuring system automatically recognises its
absolute position during installation and is ready to use immediately afterwards.
Once the controller is switched on, the LED will light up green.
6.
Swing the distance reference cover plate (1) to the designated position and hold
it down.
7.
The sensor unit is delivered with self-locking screws. Tighten these in accordance
with the torque values (see „6.5.2 Installing and connecting the read head" on
page 23). Tighten the screws in the following order: A, B, C (Fig. 33).