6
 Installation
Fig.30
6.5.2 Installing and connecting the read head
ATTENTION
Risk of material damage posed by incorrect insertion of read
head!
May result in damage to sliding parts.
• Do not allow any particulates to become caught between the sensor
slider and the scale.
• Do not allow sliding parts to come into contact with the read head.
• Do not damage the sliding parts.
Installing the read head
In the case of MONORAIL AMS systems delivered without a read head, the housing
is sealed with a cover plate (1). This must be removed prior to read head installation.
Type:
AMS 3B
Screws:
2x ISO 4762
M3x10 - A2
(self-locking)
Tightening
1.1 Nm
torques
Connecting the read head
ATTENTION
Risk of material damage posed by short-circuit currents!
The electronics in the read head are vulnerable to destruction by
short-circuit currents.
• Before connecting the cable, disconnect the power supply and
ensure that it cannot be restored without authorisation.
Connecting directly to the drive controller:
Connect the read head plug to the drive controller and tighten the swivel nut by hand.
AMS 4B
AMSA 3L
2x ISO 4762
2x ISO 4762
M2.5x10 - A2
M4x20-A2
(self-locking)
1.1 Nm
1.1 Nm
AMSABS
2x ISO 4762
M3x10 - A2
(self-locking)
1x ISO 4762
M3x4 - A2
(self-locking)
1.1 Nm