Schneeberger MONORAIL Series Mounting Instructions page 30

Profiled linear guideways and integrated measuring systems
Table of Contents

Advertisement

6
 Installation
Fig.44
Fig.45
Fig.46
28
6.6.4 Installation option 4
Installation option 4 is applicable in cases in which locating surfaces are present for
one guide rail and for both carriages. In this option, the mounting plate is fastened
with screws from underneath through the carriages.
Fig.43
1.
Remove the read head from the delivered system (see „9.4 Replacing the read
head" on page 59).
2.
Dismount the carriages from their transport rails using an MRM / MBM assembly
rail in each case. Take care that each carriage is identified with its corresponding
guide rail.
3.
Brace the locating surfaces of the carriages (ground side) against the locating
surface of the mounting plate (3) and fasten with screws.
4.
If carriages with ZCV/ZBV additional wipers are protected by an installation
protection film: prevent the protective film from slipping (see „7.3 Removing the
protective installation film for additional wipers (optional)" on page 48).
5.
Brace the reference rail (1) against the locating surfaces on the machine bed and
fasten with screws (see „6.6.1 Installation option 1" on page 25).
6.
Install clamping screws or clamping or wedge bars where required.
7.
Adjust the opposite guide rail (2) so that it is parallel and fasten it by lightly
tightening its screws.
8.
Mount the mounting plate with carriages onto the guide rails:
a) Lay the assembly rails to the front ends of the system rails.
b) Slide the carriages from the assembly rails onto the system rails.
9.
Slide the mounting plate with carriages back and forth and tighten the fastening
screws of the unsecured guide rail tightly against the carriage (see „6.3 Handling
guide rails" on page 19).
10. Install the read head (see „9.4 Replacing the read head" on page 59).