Mounded Front Covers - Honeywell NOTIFIER ID2000 Series Installation & Commissioning Manual

Hide thumbs Also See for NOTIFIER ID2000 Series:
Table of Contents

Advertisement

B (x4)
B (x4)
i
i i
i i i
G (x2)
G (x2)
I (x2)
I (x2)
View b
View b
View a
View a
D (x4)
D (x4)
E (x2)
E (x2)
H (x2)
H (x2)
997-433-000-5, Issue 5
May 2010
ID2000 Series Installation & Commissioning Manual
2.7 Moulded Front Covers
The ID2000 Series control panel is supplied with one, two
or three moulded front covers, depending upon your panel
configuration. Two moulded cover types are available; the
main and extension. All panel sizes require a main cover
kit (PN: 020-480). The larger panel sizes also require one
or two extension cover kits (PN: 020-481); the extended
versions use one extension cover and the double-extended
versions require two. The moulded front covers are also
available with high-security fasteners: main cover
(PN: 020-513); extension cover (PN: 020-514).
Observe ALL safety and anti-static precautions when
fitting the covers.
User Interface Doors (Optional)
If required, any cover can be fitted with a lockable,
transparent User Interface Door. This must be done
BEFORE the moulded cover is fitted to the back box
(refer to the instructions supplied with the User Interface
Door).
Taking suitable precautions, remove all packaging and
inspect for any damage that may have occurred during
transit. If damage has occurred, DO NOT PROCEED,
contact your supplier and refer to Section 2.4.2. If no
D (x4)
D (x4)
damage is evident, fit the main cover as follows:
1 Offer the moulded front cover (C) symmetically to the
View
View
a or b
a or b
C
2 Two types of hexagonal socket-headed M6 screw (D)
F
E (x2)
E (x2)
View
View
a or b
a or b
H (x2)
H (x2)
To remove the cover, use the appropriate tool to unscrew
the fasteners.
View
View
a or b
a or b
Note: Ensure the cover is supported when releasing the
To fit the upper extension cover (F), follow the same
procedure as described for the main cover but with the
following differences:
D (x4)
D (x4)
E (x2)
E (x2)
1 There are only two M6 screws (E), which must be
H (x2)
H (x2)
12
front of the back box in the correct orientation. The inner
top edge of the moulded front cover rests on the top flange
of the back box.
are used to fasten the cover to the back box: a. the
standard version, or b. the high-security version. The
standard version is tightened by means of a 4mm
hexagonal socket key, while the high-security version
requires a special 4mm security tool (PN: 334-068).
The tool is supplied with the cover.
last fastener!
inserted into their respective fixing locations (G). If a
PRN-ID printer is fitted, refer to step 2 below.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Notifier id2002

Table of Contents