Video Calibration - Christie H Series Service Manual

Hide thumbs Also See for H Series:
Table of Contents

Advertisement

After a few seconds, the ADC calibration status will change from Doing to Done.

Video calibration

1
Test equipment
2
Test signal
3
Test pattern
4
Inspection
items
To preform the video calibration, complete the steps below.
1. On the IR remote keypad, press Menu > Size & Position > Size Presets > Full Size.
2. Enter Factory Mode, see
3. Select ADC Calibration > Help.
After a few seconds, the ADC calibration status will change from Doing to Done.
H Series Service Manual
020-000802-03 Rev. 1 (12-2016)
Video generator (output level: 700 mv)
720P
SMPTE BAR
Check if the ADC calibration status has changed from Doing to Done.