8.4 System optional parameters (N-Link – Parameters tab)
Siren when partially set IW – This function which allows the activation of internal sirens during an intrusion
alarm (it is not related to Fire or 24hr alarms) when the system is partially set.
Sirens enabled – Enables all BUS and wireless sirens of the system. Designed for disabling the acoustic alarm
during system testing.
Administrator – restricted Service / ARC rights - Administrator authorisation (code at position 1) is required
to access the system for the ARC or service technician. In the case of remote access by a service technician to
the system via N-Link the administrator may get authorised using a keypad in the building. In the case of a local
connection by a service technician to the control panel using a USB cable the administrator may get authorized
remotely using the voice menu when a GSM communicator is connected.
Service and ARC controls the system - This is for the service and ARC technicians to control (Set / unset) all
sections and all PG outputs (ON / OFF) who require authorisation.
Duress access control – This function is to trigger a silent panic alarm by authorization only or during system
control (setting, unsetting, PG) when a user is under pressure from an intruder. A panic alarm is triggered during
system control by adding the number "1" to the last digit of the code. When a user code has the number 9 as the
last digit then during access control enter 0 as the last digit.
Alarm confirmation within one section - If confirmation reaction by another detector is set for a detector,
this confirmation option can be used to limit confirmation to the same section only (otherwise a detector from any
section can confirm an alarm). This is equally valid for intrusion detectors and for fire detectors.
Siren (IW output) when tamper is triggered - The sirens with an IW reaction acoustically indicate a tamper alarm
if the zone is unset or partially set. Sirens always indicate when the system (section) is set fully.
Reset enabled - Possibility to lock resetting the control panel with a jumper on the board. If the reset option is
disabled and the service code is lost, the control panel can only be unlocked by the manufacturer. Reset of the
control panel is described in chapter 12 Reset of the control panel.
Report unset section – System reports about an unset section when there is no movement detected within 16
hours.
Unsuccessful setting – A function processed during every setting procedure. If an instant zone is triggered within
the exit time or a delayed zone stays open when the exit time expires, the system is not set and triggers
an "Unsuccessful setting" event and records it in the history. If the supplementary GSM communicator is used it is
also reported by an SMS to a pre-set user if te event "SMS about unsuccessful setting" is enabled to be sent. It is
indicated by keypads and also by an outdoor siren. To cancel the indication about unsuccessful setting it is
necessary to press "Cancel warning indication" in the LCD keypad menu.
Alarm memory indication – Indication of alarm by a built-in LED in the detector by which the alarm was triggered.
Available for devices which support this function.
Ways of setting – Selection of the way the system gets through setting the system with an active device or fault
in the system. From the lowest level the system always sets regardless of active devices or faults to the highest level
where it cannot be set with active device (instant zone).
Authorization type – Selection of the way the system processes user authorization. From Standard authorization
(only a code or a tag) through to RFID tag confirmation by a code (if the user has assigned both) to double
authorization, which means obligatory applying of the tag and code. User code confirmation by a tag to reduce
the risk of unauthorized access or control by a third party.

8.4.1 Enrolling and erasing devices

An installed device (detector, keypad, siren, tag etc.) will only work after being enrolled on a position (address)
in the system. After the enrollment some devices occupy more positions (input expanders). There are also
devices (PG output modules) that are not enrolled on any position. You will find details in the manual of the
concerned device.
1. Device enrollment is performed through the N-Link software, the Devices tab, Enroll button Enrolling
is only possible in the Service mode.
2. You can enroll a device in several ways:
a. By pressing the tamper switch of a BUS device = closing the cover (some devices can be
enrolled by the pressing of a key – see the manual of the particular device).