8.4.2 List of applicable reactions

In the Devices tab you can set the reaction of the system activation of an enrolled device. Only such types of
reactions are offered for individual devices that make sense for the particular product. There are some devices
that cannot be assigned any reaction (e.g. an external siren).
Caution: The range of reactions can be limited by the system profile.
Instant zone alarm
Delay
Garage door
Next delay zone alarm
Instant always
Instant / delayed
Instant confirmed
Delay confirmed
Tamper alarm
24 hours
Silent panic alarm
Audible panic alarm
Fire alarm
Fire confirmation
Fire instant
Health troubles
Flooding
Key-box
Gas
Siren mute
None
None with no tamper
JA-14K(R) Security System Control Panel
Instant alarm if it is set. If an entry delay is set, an IW alarm
is released. An EW alarm is only released after expiration of the entry delay time
(more information about EW and IW - see chapter 8.5 Types of alarms).
Intrusion alarm with entry / exit delay.
Intrusion alarm with a special entry / exit delay.
In the Parameters tab you can set for this reaction that the exit delay will be
extended by an active status detector (e.g. for the time of opening
of the garage gate).
Intrusion alarm. A detector provides the same exit delay as the delayed detectors
in the same section. This detector will only provide the entry delay if it is activated
after a detector for which a delayed reaction has been set. If it is the first one to be
activated, it will release an alarm immediately. This setting makes sense
if a delayed detector is set in the same section.
Instant zone reaction. If set, then based on activation, instant including EW and IW
alarm warnings is activated also during exit delay time.
The system reacts to triggering a detector (alarm, entrance delay) when partially
set as an Instant zone, and when fully set as a Delayed zone alarm.
Instant intrusion alarm – see the chapter Confirmed intrusion reaction below.
Intrusion alarm with an entry and exit delay - see the chapter Confirmed
intrusion reaction.
Tamper alarm any time (the section does not need to be set).
Immediate intrusion alarm (the section does not need to be set).
Silent Panic alarm:
1) EW and IW not activated (see chapter 8.5 Types of alarms);
2) the keypad does not beep although otherwise it is set like this;
3) if the system can distinguish who triggered the Panic alarm (e.g. through a tag
with adopted user's identity or reverse entering of the code by the user, it does not
send Panic SMS to this user. Devices with the Silent Panic reaction cannot be
disabled by the Disabled option.
Audible panic alarm (the behaviour is the same as a Silent panic, the only
difference is that an alarm is signalled by the used siren according to the table
in chapter 8.5 Types of alarms).
Fire alarm any time (the section does not need to be set).
Fire alarm any time (the section does not need to be set), see the chapter
Confirmed fire reaction below.
Fire alarm only if the respective section is set.
Sends a health trouble report.
Sends a flood alarm
A special reaction designed for sealed key in case of emergency, etc the opening
of which will send a report to the ARC without activating the alarm with a siren.
A fire alarm triggered by a gas leakage detector can be always triggered
regardless of the state of the section.
Silencing of the internal siren with a subsequent report of the presence of a person
in the building.
Without any impact on the intrusion alarm. Tampering and supervision and fault
detection is kept; however, the device may be used to activate PG outputs.
The system reacts to detector triggering by PG output control only. None of
the alarm types are triggered (even a tamper alarm), fault detection is kept.