jablotron 100+ User Manual
Hide thumbs Also See for 100+:
Table of Contents

Advertisement

User manual

Advertisement

Table of Contents
loading

Summary of Contents for jablotron 100+

  • Page 1 User manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION OPERATING THE JABLOTRON 100 + SYSTEM ON-SITE OPERATING 2.1.1 USING THE SYSTEM KEYPAD 2.1.2 KEYPAD CODE AUTHORIZATION 2.1.2.1 ALARM SETTING 2.1.2.2 ALARM UNSETTING 2.1.2.3 DURESS ACCESS CONTROL 2.1.2.4 PARTIAL ALARM SETTING 2.1.2.5 TERMINATING A TRIGGERED ALARM 2.1.2.6...
  • Page 3 TABLE OF CONTENTS EVENT HISTORY USING THE LCD KEYPAD USING THE J-LINK SOFTWARE AND A COMPUTER LOGGING INTO MyJABLOTRON (WEB/SMARTPHONE) PERIODICAL MAINTENANCE TECHNICAL SPECIFICATIONS GLOSSARY OF TERMS...
  • Page 4: Introduction

    The JABLOTRON 100 + is very easy to control. Simplicity of control consists of two steps, authorization with a code or a RFID tag followed by pressing an individual keypad segments with assigned function on a keypad.
  • Page 5 2. OPERATING THE JABLOTRON 100 + SYSTEM CODE TYPE DESCRIPTION AUTHORIZATION Administrator his code has always full access to all sections and is authorized to control all PG outputs. The Administrator can create other Administrator and other codes with a lower level of authorization and assign them with access code (Main) to sections and PG outputs, access codes, RFID chips and cards.
  • Page 6: On-Site Operating

    2.1 ON-SITE OPERATING 2.1.1 USING THE SYSTEM KEYPAD JABLOTRON 100 + system may be controlled by a variety of access modules which let you not just control but also display statuses of individual segments. The system can be operated directly (setting or unsetting the system and other automation functions) using two-button segments on the keypad.
  • Page 7 2. OPERATING THE JABLOTRON 100 + SYSTEM Continuous red Continuous green SET / ON UNSET / OFF Flashes red Flashes green ALARM / ENTRY DELAY ALARM MEMORY Flashes red Continuous yellow ALARM / PARTIALLY SET ALARM MEMORY Continuous green EVERYTHING OK...
  • Page 8: Keypad Code Authorization

    Each user can have one code and up to two RFID chips (cards or tags). Recommended contactless chips: JABLOTRON 100 + , Oasis or other third-party chips compatible with 125 kHz EM. If higher security is required the alarm system can be set up to use confirmed authorization using RFID chips and codes (optional).
  • Page 9 2. OPERATING THE JABLOTRON 100 + SYSTEM Structure and description of the internal LCD keypad menu Allows you to cancel alarm/unsuccessful setting Cancel warning indication in all sections to which the user has indication access rights Allows you to control the system‘s sections...
  • Page 10: Alarm Setting

    2. OPERATING THE JABLOTRON 100 + SYSTEM 2.1.2.1 ALARM SETTING 1. Authorize using the keypad. 2. Press the right button 3. The command is executed Sections which can be controlled (the one which isn’t lit up) to set and the keypad acoustically indica- are lit up and the backlit indication a particular section.
  • Page 11: Duress Access Control

    2. OPERATING THE JABLOTRON 100 + SYSTEM 2.1.2.3 DURESS ACCESS CONTROL This function provides unsetting of the system in a special mode. The system seemingly unsets, however it triggers a silent panic alarm, which is then reported to selected users (including ARC).
  • Page 12: Section Control From The Menu Of The Keypad With An Lcd Display

    2. OPERATING THE JABLOTRON 100 + SYSTEM A triggered alarm in progress is indicated by a rapidly flashing red segment button and a backlit indication button. You need to authorize yourself using the keypad in order to terminate the alarm.
  • Page 13: Using The Ja-110E And Ja-150E System Keypads

    2. OPERATING THE JABLOTRON 100 + SYSTEM 2.2.1 USING THE JA-110E AND JA-150E SYSTEM KEYPADS System indicator Status indicators A, B, C, D LCD display Function buttons The keypad and the A, B, C, D RFID reader Statuses of individual sections are indicated by status indicators A, B, C, D above the LCD display and by the functions buttons.
  • Page 14 2. OPERATING THE JABLOTRON 100 + SYSTEM Structure and description of the internal LCD keypad menu Allows you to cancel alarm/unsuccessful setting Cancel warning indication in all sections to which the user has indication access rights Allows you to control the system‘s sections...
  • Page 15: Alarm Setting

    2. OPERATING THE JABLOTRON 100 + SYSTEM 2.2.1.1 ALARM SETTING 1. Authorize yourself using 2. Press the function button to set 3. The command is executed the keypad. Function buttons a particular section. and the keypad acoustically A, B, C, D will light up and It is possible to set more sections indicates the exit delay.
  • Page 16: Alarm Unsetting

    2. OPERATING THE JABLOTRON 100 + SYSTEM 2.2.1.2 ALARM UNSETTING 1. When you enter the building 2. Authorize yourself using 4. The command is executed. (triggering a detector with the keypad – the system indicator The function buttons and a “Delayed zone” reaction), will start flashing green.
  • Page 17: Duress Access Control

    2. OPERATING THE JABLOTRON 100 + SYSTEM To set the entire premises in which partial setting is enabled, hold down the button to set the control panel for 2 seconds or press it twice. After the button is pressed once it shows continuous yellow light, after it is pressed a second time it shows continuous red light.
  • Page 18: Section Control By Authorization

    2. OPERATING THE JABLOTRON 100 + SYSTEM 2.2.1.6 SECTION CONTROL BY AUTHORIZATION The service technician can configure the control panel to be controlled just by authorization. This way the status of all sections can change by authorization on a keypad (by typing an access code or using an RFID chip).
  • Page 19: Operating The System Using A Computer (J-Link)

    Depending on your country or region, a web account in MyJABLOTRON can be set up by an authorized JABLOTRON partner. The login name is the user e-mail address. The password for the first log in will be sent to this address. The password can be changed anytime in the user settings.
  • Page 20: Operating The System Using The Myjablotron Smartphone App

    2.3.2 OPERATING THE SYSTEM VIA THE MyJABLOTRON WEB INTERFACE The JABLOTRON 100 + system can be easily and conveniently operated using your computer via the internet and the MyJABLOTRON web interface, which is accessible from www.myjablotron.com.
  • Page 21: Operating The System Using Sms Commands

    J-Link software. It can be downloaded from the “Downloads” section of the www.jablotron.com website or it can be found in the control panel’s SD card. The registration code of the security system (a 15-digit code) and the telephone number of its SIM card is required to connect to the system remotely the first time.
  • Page 22: Remote Control

    2. OPERATING THE JABLOTRON 100 + SYSTEM Select the desired PG using arrows → ENTER. Pressing ENTER repeatedly will change the PG statuses (active PG is shown by a PG number in a rectangle filled with black colour Press ESC to exit the menu.
  • Page 23: Disabling Timers

    3. BLOCKING/DISABLING IN THE SYSTEM 3.3 DISABLING TIMERS To temporarily disable automated scheduled events in the system, a timer can be disabled. Disabling a scheduled event (e.g. unsetting the system from night guarding at a predetermined time) will prevent execution of that event (e.g.
  • Page 24: Calendar Events Set Up

    4. CUSTOMIZING THE SYSTEM 4.5 CALENDAR EVENTS SET UP It is possible to configure calendar events (unsetting / setting / partial setting, controlling or blocking PG outputs). The calendar events can be set up via the J-Link software in the Calendar tab. For each calendar event, action, section or PG output and event time can be set.
  • Page 25: Periodical Maintenance

    6. PERIODICAL MAINTENANCE It is necessary to have regular and timely maintenance checks performed in order to secure reliable functioning of the system. Most of the maintenance is carried out by an installation company at least once a year during periodical maintenance inspections. User maintenance consists mainly of keeping the individual devices clean.
  • Page 26: Technical Specifications

    Caller identification (CLIP) ETSI EN 300 089 JABLOTRON ALARMS a.s. hereby declares that the control panels JA-103K a JA-107K are in a compliance with the relevant European Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU, when used as intended. The original of the conformity assessment can be found www.jablotron.com – Downloads section.
  • Page 27: Glossary Of Terms

    (following the system status, alarm status, faults, etc.). Home Automation In addition to providing an intruder alarm system, the JABLOTRON 100 + offers a number of other features. Among the most popular functions are: electrical door locks, automated light switches using motion detectors, and the remote control of appliances (electrical heating, garage doors, gates, entry barriers, etc.).
  • Page 28 9. NOTES...
  • Page 29 9. NOTES For questions and further information contact your installer. MMD55300...
  • Page 30 M-ENJA100+-USER www.jablotron.com...

This manual is also suitable for:

Ja-103kJa-107k

Table of Contents