Individually bought devices should be enrolled to Azor using a registration code. The code
consists of ten digits and it is in the following format: 123-4567-890. Enrollment (or removal)
of a device is done with a computer by filling the registration code in (or erasing it from)
the respective position of the device at the Detectors page. If the registration code is illegible
(e.g. damaged label) it can be enrolled by A-Link instead. Choose a position to which you
want to enroll the device and click on the Enroll button. Insert the battery into the device.
The registration code will be displayed in the field as a confirmation of successful enrollment.

AZ-10T RFID tag

There is a sticker with a registration code on a new RFID tag. If the RFID tag code is no
longer legible, please use the RFID tag reader and A-Link software to enroll it. Choose the
Tag number field in the Users window and click on the Enroll button. The code will be
enrolled after pressing SET on the AT-10D RFID tag reader and scanning the RFID tag. As
a confirmation of successful enrollment, the registration code will be displayed in the field.
Note: Azor uses special security RFID tags. No other RFID tags can be enrolled.

AZ-10M door-opening detector

Besides detecting door and window opening, the detector can also report e.g. the
movement of objects etc. You can also connect an external sensor to it.
Terminals:
INPUT
serves for connecting external alarm sensors. When the GROUND terminal is
disconnected an alarm signal is sent (identical to that of reporting door
opening).
TAMPER
serves for connecting external tamper sensors. When the GROUND terminal
is disconnected a tamper signal is sent (identical to that of reporting detector
opening).
GROUND
common terminal. If the INPUT or TAMPER terminal is not used, it must be
permanently connected to this terminal.
Internal switches:
1
DEL the detector provides an entrance delay*
INST the detector does not provide an entrance delay*
2
MG EN the built-in magnetic sensor is enabled
MG DIS the built-in magnetic sensor is disabled (only INPUT terminal activation is
reported)
*) applies only if a "default" reaction is set for the detector
Low battery indication
When the detector batteries are low, Azor sends an informative message. Besides that the
detector LED flashes when you open the door (outside test mode).
MLO51206

System extension

- 18 -