7. Setting of the system
Functions of the system can be customized in the programming mode. Programming can be performed by entering programming
sequences from the control panel keypad. A more convenient method is with the use of a connected PC and the ComLink software.
Settings can also be downloaded directly from a central monitoring station. However, the setting of parameters and data for communi-
cation with a monitoring station is not included in this manual and it is provided only to the providers of this service.

7.1. List of control panel programmable parameters

Function
Enrolling of detectors and controllers
Exit / Entrance delay
Alarm duration
Function of PgX output
Function of PgY output
User recorded Message & phone numbers: editable
in the user mode*
Radio signal jamming regular testing
Regular communication check enabled
RESET enabled
Teaching of the control panel to a UC-216, etc.
No code requested (effects F1, F2, F3, F4 & F9)
Partial (Home) arming enabled (F2)
Built in siren alarm enabled
Exit delay audible indication enabled
Partial arming exit delay audible indication
Entrance delay audible indication enabled
Arming & disarming chirp sound enabled
Built in siren in Disarm & Partial arming enabled
Wireless siren alarm enabled
Indication of system problems when arming
New Service Code setting
Dialing method*
Triggering of the dialer with a Panic alarm*
Triggering of the dialer with an Intruder alarm*
Triggering of the dialer with a Fire alarm*
Triggering of the dialer with a Tamper alarm*
Triggering of the dialer with a Technical alarm*
Telephone line checking enabled*
Store telephone numbers for voice message*
Pager dialing programming*
Erase telephone number*
Record voice message*
Real time and date setting
Alarm system JA-60 "COMFORT"
sequence
options
1
1& 6 scrolling, hold 2 to erase
position, 4 to erase all
x = 1 to 9 (x 10sec.)
21x
x = 1 to 9 (min.), for x=0 it
22x
will be 10 sec.
x = 0 to 7 (0-Chime, 1-Fire,
23x
2-Arm, 3-Panic, 4-Alarm,
5-Door, 6-Home, 7-NO AC
x = 0 to 7 (0-Chime, 1-Fire,
24x
2-Arm, 3-Panic, 4-Alarm,
5-Door, 6-Home, 7-NO AC
251 = YES
25x
261 = YES
26x
271 = YES
27x
281 = YES
28x
299
will send enrolling signal
301 = YES
30x
311 = YES
31x
321 = YES
32x
33x
331 = YES
341 = YES
34x
351 = YES
35x
361 = YES
36x
371 = YES
37x
381 = YES
38x
391 = YES
39x
nSC = new Service Code
5 nSC nSC
(must be entered twice)
90x
901 = tone
911 = YES
91x
921 = YES
92x
931 = YES
93x
941 = YES
94x
951 = YES
95x
991 = YES
99x
xx...x = tel. number, y =
7xx..x F y
memory 1 to 4, pause = F0
x..x = provider tel. number
7x.xF9z..zF5
z..z = pager number + mess.
y = memory 1 to 5, entering
7F0Fy
7F0F0 erases all
message:
8 0 (hold 0)
4 hh mm DD MM YY
* Setting of these parameters in following sequences is available only for a control panel with a built in optional dialer
-
9 -
factory
d.
-
30sec.
4min.
Chime
Arm
250 = NO
NO
260 = NO
NO
270 = NO
NO
280 = NO
YES
-
300 = NO
YES
310 = NO
YES
320 = NO
YES
330 = NO
YES
340 = NO
NO
350 = NO
YES
360 = NO
NO
370 = NO
YES
380 = NO
YES
390 = NO
NO
6060
900 = pulse
tone
910 = NO
YES
920 = NO
YES
930 = NO
YES
940 = NO
YES
950 = NO
YES
990 = NO
NO
1:
2:
3:
4:
5:
00 00 01 01 00
note
MDY51306

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ja60x

Table of Contents