Codes for JA-14K(R)
Code format:
Service (default):
Administrator (default):
ARC code:
Warning: When the system profile setting is changed, all defined codes are erased and only default codes are
are pre-set to default values. All access RFID tags remain.
The service default code is filled in automatically by the N-Link software, so from the first activation until a code
change the software does not request them. However for security reasons immediately after installation is
finished, it is imperative to change all default codes.

1.2.1 Change of access codes

The creation or change of user codes or RFID tags can be performed by the system Administrator or a service
technician. A new code or RFID tag can be assigned to the user with pre-set authorization. Only the service
technician has rights to create such a user using N-Link SW.
Access codes can be added and changed by:
− the administrator from an LCD keypad (condition: the PC has to be disconnected from the control panel,
no remote or local connection and a user with the required authorization)
− A service technician and N-Link software (condition: the enabled parameter Service and ARC can control
the system)
Every user code can be set to an arbitrary value considering the code length given by the selected system
profile, but the control panel restricts using the same code value for another user which has already been used
in the system. Only system Administrator(s) is/are fully responsible for editing already-existing user codes and
assigning new codes.

1.2.2 Security access codes and RFID devices

The control panel allows you to assign one code (accordind to the selected profile) and one RFID tag to every
user to be authorised. Authorisation is required when the system is operated with a keypad. The security level is
adequate for this fact and it can be represented by numbers.
Calculating code combinations according to 1 user is shown in the following examples:
Control panel parameters
Duress access control – OFF
Standard authorization – ON
Duress access control – ON
Standard authorization – ON
Duress access control – OFF
Double authorization - ON
Duress access control – ON
Double authorization - ON
Using RFID tag only with no digit
code
Example:
Selected profile:
Total number of users stored in the system:
Duress access control:
Number of code combinations:
Increasing the security level of codes:
Select a multiple digit code (6-digit codes – System profile EN-50131-1)
Select a higher level of authorization to "Double authorisation", where the standard valid access code and
a RFID tag are required to be both applied
JA-14K(R) Security System Control Panel
Default profile
(4-digit codes)
nnnn
1010
1234
1000
4-digit codes
4
= 10
– (Total number of users
stored in the system)
4
≤ 10
– ((Total number of users
stored in the system) * 3)
8
4
= 10
* (10
– (Total number of
users stored in the system))
8
4
≤ 10
* (10
– ((Total number of
users stored in the system) * 3))
8
= 10
= (100.000.000)
Default
Max 19
Disabled
4
10
– 19 = 9 981 combinations / users
8 / 72
EN50131-1 profile,
(6-digit codes)
nnnnnn
101010
123456
100010
6-digit codes
6
= 10
– (Total number of users
stored in the system)
6
≤ 10
– ((Total number of users
stored in the system) * 3)
8
= 10
* (10
users stored in the system))
8
≤ 10
* (10
users stored in the system) * 3))
8
= 10
~ 4-digit codes
6
– (Total number of
6
– ((Total number of
= (100.000.000)
MNX22101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ja-14kJa-14kr

Table of Contents