Section name – naming of sections is used to make textual event reports (SMS), showing on keypad and
memory readout, for a better recognition when reported (e.g. Ground Floor, Store, ...)
Common section – allows you to select that a section is automatically set if all the sections for which it is
a common one are set (suitable for corridors, staircases and other common areas). Warning of the limitation of
the possible use of the keypad functional button for the common section: if any of the sections has been unset
separately, the common section functional button cannot be used to unset the remaining sections.
These sections must be unset separately.
Section disabled – disabling possibility to set section, (blocking a section means that all devices assigned
to the section are collectively disabled), indicated by a red dot. You cannot block the section that the control
panel is assigned to. A section may only be blocked by a service technician (through N-Link).
Warning: When section where the radio module has been assigned is blocked then this radio module stops working from all sections. That's
why we recommend to assign it to section 1 where is control panel as well. When section which is part of Common functional button is
blocked it is indicated by yellow colour (it cannot shows all its sections are fully set or unset).
Status – indicates the current status of a section (Unset, Set, Exit Delay, Entrance Delay, Partially Set, Alarm,
Alarm Memory, Disabled, Service mode). By pressing the button the system can be controlled according
to the authorization given by your login (it changes the section state – partially set / set / unset...).
Note – it allows you to describe details of a section for easier orientation during annual inspections etc.

10.3 Devices tab

It is used to enroll an installed device in the system and to set its parameters. The tab will display 32 positions
for devices to be enrolled. The control panel is automatically enrolled on Position 0 in Section 1 and it cannot be
removed or deleted. To make changes in this tab you must be in the Service mode.
Name - it is used in textual reports of events and in the memory readout (example Main door).
Type – displays the type of the assigned device. An empty position allows you to enroll a new device. Enrolling
devices, see chapter 8.4.1 Enrolling and erasing devices.
Section – determines to which monitoring section the device will report events (alarm, tampering, fault ...).
Note: division of a building into sections - see chapter 10.2 Sections tab.
Reaction – defines which reaction will be released by activation of the particular device. If a device does not
have any alarm input (e.g. JA-111R), it cannot be assigned a reaction. You will find a description
of all the reactions in chapter 8.4.2 List of applicable reactions.
JA-14K(R) Security System Control Panel
43 / 72