10.11.1 Requrements for the setup of transmission paths to an ARC

The JA-14K(R) control panel can establish transmission paths to the ARCs according to European standards
EN 50136-1 and EN 50136-2. The following table states the individual parameters to comply with a specific ATS
class. There must be full support of the ATS classes on the ARC side.
Useable
ATS
interfaces
Class
(Alarm
protocols)
PSTN / GSM /
LAN
SP2
(JABLO IP, SIA
IP, SIA CID)
GSM / LAN
SP3
(JABLO IP, SIA
IP, SIA CID)
GSM / LAN
SP4
(JABLO IP, SIA
IP)
GSM / LAN
SP5
(JABLO IP, SIA
IP)
LAN + PSTN
DP2
(JABLO IP, SIA
IP)
LAN + GSM
DP3
(JABLO IP, SIA
IP)

10.11.2 Transmission paths

For GSM(GPRS) and LAN communication using IP protocols:
1) Protocol ANSI SIA DC-09, SIA IP (DC9), methods DCS or ADM_CID (data message)
- encryption according to the AES standard with 128, 192 or 256 bit keys
- unique message time stamps inserted
- very precise time synchronization between alarm system and ARC
2) Protocol JABLO_IP (data message)
- Proprietary Jablotron protocol
- 256 bit encryption
- unique message time stamps inserted
- very precise time synchronization between alarm system and ARC
3) JABLO_SMS (data SMS messages)
- based on JABLO_IP protocol with floating data encryption
JA-14K(R) Security System Control Panel
Connection
Connection
check at
check time
fixed time
Optional
1× per 24 hrs
Not allowed
1× 30 min
Not allowed
1× 3 min
Not allowed
1× 1 min
Not allowed
1× 30 min
Not allowed
1× 3 min
Fault
when
event
Number of
report
repeats
delay over
limit
120 s
2
60 s
2
60 s
3
30 s
6
60 s
2
60 s
3
59 / 72
Period of
waiting after
Encryption
an
System time
unsuccessful
Event time
attempt
Optional
30 s
Required
Required
Optional
30 s
Required
Required
Required
20 s
Required
Required
Required
5 s
Required
Required
Optional
30 s
Required
Required
Required
20 s
Required
Required
MNX22101