List of control panel programmable parameters
Function
Enrolling of detectors and controllers
Exit delay
Entrance delay
Alarm duration
Function of PgX output
Function of PgY output
Voice message & phone numbers: editable in the
user mode
Radio signal jamming regular testing
Regular communication check enabled
RESET enabled
Control panel teaching to a UC-2xx, subsystem,...
No code requested (effects F1, F2, F3, F4, F8 & F9)
Partial (Home) arming enabled (F2)
Siren alarm enabled
Exit delay audible indication enabled
Partial arming exit delay audible indication
Entrance delay audible indication enabled
Arming & disarming chirp sound enabled
Siren in Disarm & Partial arming enabled
Wireless siren alarm enabled
Indication of system problems when arming
Split control panel (A, B & C sections)
Addressing of wireless detectors to sections
Addressing of user codes to sections
Addressing of wireless controllers to sections
Automatic arming/disarming setting
New Service Code setting
User Mode entering
Real time and date setting

8.1. Testing of the system

In the programming mode (indicated by a „P") no alarm can be triggered. The control panel will confirm receiving any
signal from an enrolled detector or another JA-60 wireless item. It will make a beep - press F to select the loudness of the
beep (0-I-II) and the LED display will show which signal was received. Some detectors (JA-60P, JA-60N etc.) have an
extra testing mode, which is usually activated for 5 minutes after the detector's cover is attached (see manuals of the
particular detectors).
Just as in the programming mode, the signals from all enrolled items are confirmed in the user mode (confirmed by a
"U"). The user mode is accessible with the Master code and the supervisor of the system can use this mode to replace
batteries in items or for system testing. To open the user mode enter F 0 MC (= Master Code) when the control panel is
disarmed.
Alarm system JA-60 "COMFORT"
sequence
options
1& 6 scrolling, hold 2 to erase
1
position, 3 all controllers, 4 to
erase all items
20x
x = 1 to 9 (x 10sec.)
x = 1 to 9 (x 10sec.)
21x
x = 1 to 8 (min.), for x=0 it
22x
will be 10 sec., for x=9 15min.
x = 0 to 8 (0-Chime, 1-Fire,
23x
2-Arm, 3-Panic, 4-Alarm,
5-Door, 6-Home, 7-NO AC,
8-Phone
x = 0 to 8 (0-Chime, 1-Fire,
24x
2-Arm, 3-Panic, 4-Alarm,
5-Door, 6-Home, 7-NO AC,
8-Phone
251 = YES
25x
261 = YES
26x
271 = YES
27x
281 = YES
28x
will send enrolling signal
299
301 = YES
30x
31x
311 = YES
321 = YES
32x
331 = YES
33x
34x
341 = YES
351 = YES
35x
361 = YES
36x
371 = YES
37x
381 = YES
38x
391 = YES
39x
6901 = YES
690x
nn– zone n., s- section
61 nns
62 nns
nn– code n., s- section
nn– controller n., s- section
63 nns
n- 0-9, a-action #, hh-hours,
64nahhm
mm-min.
m
nSC = new Service Code
5
nSC nSC
(must be entered twice)
Switching to the User mode
6999
4 hh mm DD MM YY
- 12 -
factory
d.
-
30sec.
30sec.
4min.
Chime
Arm
250 = NO
NO
260 = NO
NO
270 = NO
NO
280 = NO
YES
-
300 = NO
YES
310 = NO
YES
320 = NO
YES
330 = NO
YES
340 = NO
NO
350 = NO
YES
360 = NO
NO
370 = NO
YES
380 = NO
YES
390 = NO
NO
6900 = N0
NO
1-10 A
only when split
all A
only when split
all A
only when split
all off
6060
-
00 00 01 01 00
when the LED display displays „P"
note
MDY51319