88
display specifies mode of the control panel:

2 Controlling the system

The system can by controlled by keypads, remote controls or by a PC with the
Comlink Software.
User codes
Can be used to arm and disarm the system or to reset an alarm. There can be up to
14 different user codes for individual users. The system stores to its memory which
code was used for which operation as well as the time &date of usage. This data can
go to a Central monitoring station and can also be viewed using a PC with Comlink
software.
All user codes are empty as a factory default and should be programmed by the
supervisor (see section 3.2).
Alarm system JA-63 „PROFI"
Telephone line
digital bus
communication
failure
error
user mode
home arming
A section armed
B section armed
complete
arming
bypass
key pressed
programming
mode
indicated event (Tamper or Failure) was caused
by the telephone line
indicated event (Tamper or Failure) was caused
by a device (keypad or PC) connected to the
wireless keypad lost connection with the control
self testing error – call installer
tab. 1
authorized supervisor can test, bypass zones, change
batteries, record voice messages, program tel.
numbers and adjust internal clock in this mode
system is partially armed – particular detectors are
bypassed (someone remains in the house)
A section is armed (split system)
B section is armed (split system)
system is completely armed
warning that some detectors are bypassed –
indicated while arming
waiting for more data to complete the entry
for installer programming and testing
tab. 2
- 4 -