Current status – color-coded information about the current status of a PG output. Green description
corresponds to the green light of the functional button; red description corresponds to the red light of the button.
Test PG output – possibility to control an output manually from the computer using N-Link SW. Depending on
the selected function it will enable (or disable) the particular PG, if it´s not currently blocked.
Note – makes it possible to describe details of a PG output, its use, special behaviour, notification of activation
together with other outputs etc.

10.5.1 Map of PG output activation

By selecting Activation in the PG outputs tab you will enter the map of activation links. The map determines
what action the output responds to.
By dialling in from user's tel. numbers – defining users that are authorized to activate a PG output by calling from
their phone when a supplementary GSM or PSTN communicator is connected. Phone numbers used for the ringing
activation must not be hidden (the CLIP service must not be deactivated for them). The term "ringing" means that
after dialling the phone number the caller waits for at least one ringing tone (however, up to the answering setting,
see the number of ringing tones of incoming calls in the communicator settings) and terminates the call. The PG
output switches on when call hangs up. If the call is answered by the control panel, the output will not be activated.
By a device – enables activation of a PG output by a device (detector activation, pressing a tag etc.).
The setting is linked to the Devices tab. One device may only activate one PG output.
Reaction to – enables activation of an output by a selected event in the system (e.g. setting, alarm, power
supply failure, error etc.). For an internal status (29 internal statuses altogether, see the following table) you can
set the group of sections the signal will be accepted from (the OR logic). The concerned PG output may be set
to copy the status of another PG output or several other outputs where the mutual logic is selectable
(OR or AND). The last item in the menu allows you to set activation of an output and its deactivation in response
to a completely different event (e.g. activation in case of an alarm, but deactivation by unsetting only).
Active device – list of devices that activate the concerned PG output with their activation, for instance
a photo from a PIR with a camera (function can be set in the device's internal settings) or acoustic indication by
sirens, etc.
By a calendar event – list of scheduled events that activate or deactivate or block the concerned PG output
(information window)
By a keypad – Shows the list of keypads and remote controllers in system with ability to control specific PG
output.
Warning: The PG outputs are not functional if the system is in the Service mode. By pressing the Test button all
PG outputs can be tested. On activation of the Service mode all the PG outputs get disabled.
After exiting of the Service mode from N-Link their re-activation is offered.