Protection against a code breaking attempt:
The control panel counts the attempts at wrongly entered codes and if the 10
triggers the tamper event "Code breaking attempt", alarm is triggered and reports this event to predefined
numbers. No additional blocking of entering other codes into the system is applied. After a valid code entry, the
counter of wrongly entered codes is reset and the triggered alarm terminated. This counter is pre-set to 10
attempts and it cannot be changed.

1.3 Regular system check (maintenance)

The whole security system requires periodical testing of its correct functioning and that of all its parts but also
cleaning, external visual checks (dust and dirt, usually performed by the system user) and internally (spider
webs, insects, battery status, etc... performed by service technician). Some specific parts of the system are able
to perform a self-test and a possible fault report to the control panel and it informs about this status according to
the settings. Almost all maintenance steps are required to be done by a service technician during the annual
system check.
The main backup battery is tested periodically a few times per minute by the control panel using a load test.
Wireless device batteries (in detectors, keypads, sirens, remote controllers) are automatically tested with every
link test transmission. The system reports a low battery from every enrolled device from the moment when it
appears until its replacement via a pre-set SMS report and simultaneously on the LCD keypad. Replacement of
the batteries can only be performed by a service technician. When a battery is removed it is necessary to wait a
few moments (20 s) for discharging any internal capacitors and then insert a new battery.
Overview of recommended maintenance / function control:
Device type
Fire detectors
Panic buttons
Detectors
Keypads
Sirens
Remote controllers (RC)
Alarm state
Backup battery in the
control panel
Programmable outputs
(PG)
All the procedures recommended by the system producer don´t have a higher priority than local regulations and decrees.
JA-14K(R) Security System Control Panel
Description
Test of functions; inform the ARC agency
before you proceed!
Clean up the dust and dirt.
Battery check (BUS and wireless devices)
Test of functions; inform the ARC agency
before you proceed!
Battery check, measuring the voltage,
physical state.
Clean up the dust and dirt.
Test of functions; test of RF range for
wireless detectors. For detectors with a
built in camera test by taking a picture.
Battery check, measuring the voltage of
every battery, physical state, etc.
Clean up the dust and dirt.
Test every button, functional buttons and
RFID sensor; test the RF range for
wireless keypads.
Battery status check and their physical
state, measuring the voltage of every
battery, etc.
Clean up the dust and dirt, insects, check
water penetration to PCB, etc.
Test of functions; test the RF range for
wireless sirens.
Check batteries or backup batteries,
measuring, physical state, measuring the
voltage of every battery
Test of functions; RF range, low batt
indication check. Cleaning up or plastic
housing replacement.
Test of communication to ARC, voice calls
and SMS reporting.
Test during mains (AC) disconnection and
measuring the voltage of a backup battery
after 5 minutes of no mains power.
Test of functions; RF range of wireless
modules
th
Who does
the action
Administrator
Administrator
Service technician
Administrator
Service technician
Administrator
Service technician
Service technician
Administrator
Service technician
Service technician
Service technician
Service technician
Service technician
Administrator or
Service technician
Administrator or
service technician
Service technician
Service technician
9 / 72
attempt is reached, the system
Frequency
of the action
Once per month
Twice per year
Once per year
Once per month
Once per year
Once per year
Once per year
Once per year
Twice per year
Once per year
Once per year
Once per year
Once per year
Once per year
Once per year
Once per year
Once per year
Once per year