11.17. Partial arming exit delay audible indication

Partial arming with
(F2) provides an exit delay for delayed
reaction detectors in section A. The exit delay for partial arming
can be indicated by the „beeping" of the keypad (for the last five
seconds the beeping is faster).
options:
3 4 1
indication enabled
3 4 0
indication disabled
Factory default setting: indication disabled
Note: when this indication is disabled, the
partial arming and disarming will
regardless of the 36x setting.

11.18. Entrance delay audible indication

The entrance delay can be indicated by a rapid „beeping" of the
keypad. This indication can be disabled with this setting.
options:
3 5 1
indication enabled
3 5 0
indication disabled
Factory default setting: indication enabled
11.19. Arming and disarming chirps with hard wired
siren
The control panel can confirm on the SIR output arming (1
chirp), disarming (2 chirps), disarming with information in the
memory (3 chirps), bypass or not ready component when arming
(4 chirps). This parameter sets chirps on.
options:
3 6 1
siren chirps enabled
3 6 0
siren chirps disabled
Factory default setting: siren chirps disabled
Note: setting of chirp sounds is valid even if the siren is disabled
for alarms with parameter 320. Partial arming is always silent, if
sequence 340 is selected. Chirp sounds can also be generated
with the JA-60A wireless siren (self-contained setting in the
wireless siren).
11.20. Siren alarm in Disarm & Partial arming
The SIR output can be disabled for alarms during the Disarm &
Partial arming of the control panel (while somebody is indoors).
If the siren output is completely disabled for alarms with
parameter 320, this setting has no effect.
options:
3 7 1
alarm in disarm & partial arming enabled
3 7 0
alarm in disarm & partial arming disabled
Factory default setting: enabled

11.21. Wireless siren alarm

The wireless siren alarm function can be disabled with this
parameter. This setting will have no influence on the outdoor
wireless siren chirp sound function if enabled in the siren. This
setting has effect only when the control panel is equipped with a
65R module:
options:
3 8 1
siren enabled
3 8 0
siren disabled
Factory default setting: siren enabled
Alarm system JA-65 MAESTRO
sequence: 3 4 x
confirmation of
automatically be silent,
sequence: 3 5 x
sequence: 3 6 x
sequence: 3 7 x
sequence: 3 8 x
- 12 -

11.22. Indication of system problems when arming

The system regularly checks the conditions of all items
(detectors, keypads etc.). This setting ensures that the user will
be warned with 4 rapid beeps after arming, if any component of
the system is not ready for arming. Cause of the problem (for
example permanently triggered detector, lost communication
etc.) will remain displayed on the keypad. If the user ignores this
warning, the system will arm after the exit delay, then an alarm
will be triggered and finally the problematic item will be
bypassed for this arming period. After disarming in such a mode,
three beeps will be generated as well.
When the indication is not selected, the problematic item will be
bypassed when arming with neither warning nor alarm.
If a permanently activated detector is deactivated during arming
(for example your main door is not closed), the bypass of this
detector will be canceled automatically and the detector will be
ready to trigger an alarm after it is activated (if you close the
door after the system is armed).
options:
3 9 1
warning enabled
3 9 0
warning disabled
Factory default setting: warning disabled
Note: if this indication is enabled, the problems will also be
indicated
if
there
programming or user mode.

11.23. Control panel splitting

The control panel can be split in to 2 independent sections A
and B, with a shared common area C. This way the system can
be operated by two independent user groups. In fact the system
in this mode works like two independent systems. If the system
is split to the sections with this setting, it is possible to address
detectors (both wireless and wired), user codes and remote
controls to the above sections (see 11.2., 11.31 and 11.32.).
options:
6 9 0 0
no splitting (partial arming available in this mode)
6 9 0 1
splitting to sections A, B and common C (C is
armed only when both A and B are armed)
Factory default setting: no splitting

11.24. Only first source of alarm is recorded

When any item triggers the alarm 4 times in a row the system
will bypass it until any other events occurs. But it is possible to
set the limit at the incoming events so only the very first event
during the entire alarm will be recorded. This function is useful
especially if the system contains a GSM communicator in order
to decrease quantity of the SMS messages. This setting is valid
for all kinds of the alarm.
Options:
6 9 1 0
All sources of alarm are recorded
6 9 1 1
Only first source of alarm is recorded
Factory default setting: All sources of alarm are recorded

11.25. Alarm triggered by opened zone when arming

If the "indication of system problems when arming" (see 11.22)
is enabled, it is also possible to test the status of the detectors
after expiring the exit delay. If any item is activated then in case
of instant zone the alarm will be triggered immediately, in case
of delay zone the entry delay will start.
sequence: 3 9 x
are
any
when
leaving
sequence: 690 x
sequence: 691 x
sequence: 692 x