7 Switching the system ON

1. Check connection of the BUS cables.
2. Verify whether a microSD card is present in its holder on the control panel board.
3. Check whether the mains supply cable is correctly connected to the control panel and that the supply cable
is firmly fixed.
4. Insert a battery in the control panel and fix it in the housing (using the strap)
Caution - the backup battery is delivered in a charged condition, it must not be short-circuited!
5. Connect the supply leads of the battery. Mind the correct polarity (red +, black -).
6. Switch on power from the mains and check the LED indicators on the control panel:
a. the green LED starts flashing (BUS function).
b. the red LED flashes – logging in to the GSM network by supplementary GSM communicator.
c. the red GSM LED goes out
d. the red LED permanently lit – the control panel has not logged in to the GSM network.
7. When the connected BUS devices start flashing yellow, assign them to the system, see chapter 8.4.1
Enrolling and erasing devices.
8. Perform configuration of the keypads,
9. Set the required functions and test the system, see chapter 10.7 Parameters tab.

8 System configuration

The security system (protected premises – building) can be split into independent parts – sections. Every
section can also be guarded as a whole section or only part of it. This is called partial setting. Detectors with
the enabled parameter "Internal" don´t guard in such a mode.

8.1 The system profiles

System profile selection allows you to globally pre-set the following system parameters (N-Link / Parameters
tab) to modify system behaviour to comply with the given norm and the required security grade. These options
could be blocked when a specific profile is selected for changes.
Caution: setting individual parameters by selection of a system profile doesn´t guarantee that the installed
system complies with security grade 2. Only correct system design (using the right devices) and correct
installation with CLC/TS 50131-7 requirements and ARC service implementation can ensure security grade 2.
Classification of the JA-14K(R) control panel and individual system devices of the JA-10 system for security
grade 2 is just the basic input, and according to that fact the security grade of the protected premises can be
set.