12.20. Wireless siren alarm

The wireless siren alarm function can be disabled with this parameter. This setting will have no influence on the outdoor
wireless siren chirp sound function if enabled in the siren. This setting has effect only when the control panel is equipped
with a 65R module:
options:
3 8 1
3 8 0
Factory default setting: siren enabled

12.21. Indication of system problems when arming

The system regularly checks the conditions of all items (detectors, keypads etc.). This setting ensures that the user will be
warned with 4 rapid beeps after arming, if any component of the system is not ready for arming. Cause of the problem (for
example permanently triggered detector, lost communication etc.) will remain displayed on the keypad. If the user ignores
this warning, the system will arm after the exit delay, then an alarm will be triggered and finally the problematic item will
be bypassed for this arming period. After disarming in such a mode, three beeps will be generated as well.
When the indication is not selected, the problematic item will be bypassed when arming with neither warning nor alarm.
If a permanently activated detector is deactivated during arming (for example your main door is not closed), the bypass of
this detector will be canceled automatically and the detector will be ready to trigger an alarm after it is activated (if you
close the door after the system is armed).
options:
3 9 1
3 9 0
Factory default setting: warning disabled
Note: if this indication is enabled, the problems will also be indicated if there are any when leaving the programming or user mode.

12.22. Control panel splitting

The control panel can be split in to 2 independent sections A and B, with a shared common area C. This way the system
can be operated by two independent user groups. In fact the system in this mode works like two independent systems. If
the system is split to the sections with this setting, it is possible to address detectors (both wireless and wired), user
codes and remote controls to the above sections (see 12.2., 12.23 and 12.24.).
options:
6 9 0 0 no splitting (partial arming available in this mode)
6 9 0 1 splitting to sections A, B and common C (C is armed only when both A and B are armed)
Factory default setting: no splitting

12.23. Only first source of alarm is recorded

When any item triggers the alarm 4 times in a row the system will bypass it until any other events occurs. But it is
possible to set the limit at the incoming events so only the very first event during the entire alarm will be recorded. This
function is useful especially if the system contains a GSM communicator in order to decrease quantity of the SMS
messages. This setting is valid for all kinds of the alarm.
Options:
6 9 1 0 All sources of alarm are recorded
6 9 1 1 Only first source of alarm is recorded
Factory default setting: All sources of alarm are recorded

12.24. Alarm triggered by opened zone when arming

If the "indication of system problems when arming" (see 10.21) is enabled, it is also possible to test the status of the
detectors after expiring the exit delay. If any item is activated then in case of instant zone the alarm will be triggered
immediately, in case of delay zone the entry delay will start.
Options:
6 9 2 0 test disable
6 9 2 1 test enable
Factory default setting: test disabled