Technical Specifications - jablotron JA-10 Series Manual

Control panel
Hide thumbs Also See for JA-10 Series:
Table of Contents

Advertisement

16 Technical specifications

Parameter
Type of installation
Nominal control panel
voltage / frequency / fuse
Operation voltage range
Electric power / current
Protection class
Back-up battery
Low battery voltage
(fault indication)
Maximum battery charging time
BUS voltage / max. voltage
ripple (red-black)
Max. continuous consumption
from the control panel BUS +RJ
@ 12 hours backup (2.6 Ah)
@ 24 hours backup (2.6 Ah)
Max. number of devices
Max. number of sections
Max. number of users
Max. number of PG outputs
Alarm connection
Alarm system classification
@ according to standards
@ environment
@ operational
temperature / humidity
@ power
@ event history
@ system reaction to
communication loss
@ reaction to invalid code entry
@ ATS classification
JA-14K(R) Security System Control Panel
Fixed installation
~ 230 V / 50 Hz, T200 mA fuse 250 V 5 x 20 mm
~ 115 V / 60 Hz, T400 mA fuse 250 V 5 x 20 mm
~ 195 V ÷ 250 V
~ 110 V ÷ 120 V
Max 23 VA / 0.1 A
II.
12 V; 2.6 Ah max. (lead-acid)
≤11 V
48 ÷ 72 hrs
12.0 ÷ 13.8 V
/ ± 100 mV
DC
400 mA permanently (1000 mA for 5 minutes)
LAN OFF: 125 mA – consumption of modules JA-190X (Y)
LAN ON:
85 mA – consumption of modules JA-190X (Y)
LAN OFF: 62 mA – consumption of modules JA-190X (Y)
LAN ON:
42 mA – consumption of modules JA-190X (Y)
32
4
16
4
JA-10 BUS – dedicated wiring
Wireless connection (with JA-111R) – unspecified wireless connection,
JA-10 wireless protocol
Security grade 2 / environmental class II
EN 50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3, EN50131-10,
EN 50136-1, EN 50136-2
indoor general
-10°C to +40°C, relative humidity 75% no condensation
Type A – primary supply with a charged backup battery
approx. 7 million latest events, incl. date and time
Fault or tamper – according to the pre-set profile
@ BUS until 10 s
@ wireless communication in 2 hrs (report)
@ wireless communication in 20 min block system to be set
After 10 wrong code entries a tamper alarm is triggered and according to
the selected profile it blocks all control devices for 10 min
Supported ATS classes : SP2 – SP 5, DP2 – DP3
SPT:
type Z
Operation type:
Pass-Througth
Built-in LAN:
SP2 – SP5 (with IP protocol)
JA-190Y
SP2 – SP5 (with IP protocol)
JA-190X
SP2 (with Contact ID protocol)
LAN + JA-190Y
DP2 – DP3 (with IP protocol)
LAN + JA-190X
DP2 (with IP / CID protocol)
71 / 72
JA-14K(R)
MNX22101