Landis+Gyr E230 User Manual page 77

Residential electricity meter
Table of Contents

Advertisement

Error handling
Display
Description
00004000
Power-fail data
failed
checksum.
00002000
Calibration
value failed
checksum.
00001000
UNUSED
00000800
UNUSED
00000400
UNUSED
00000200
UNUSED
00000100
UNUSED
00000008
Error in
Parameter Data.
00000040
UNUSED
D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual
If error is persistent
Meter operation may be
compromised. Billing
based on energy
registers after the error
occurrence is not
reliable. Error will only
occur during the power-
up sequence. This error
is set, if the checksum of
the power-fail data is
incorrect during power-
up.
Meter operation may be
compromised. Billing
based on energy
registers after the error
occurrence is not
reliable. Error will only
occur during the power-
up sequence. This error
is set, if the checksum of
the calibration data is
incorrect during power-
up.
Meter operation may be
compromised due to
incorrect or corrupt
parameterisation.
If error is transitional
Clear Error Register
F.F.0 on display and
readout by "Reset Error
Register" (W2 C150)
command using
.MAP110 or by power-
cycle.
Clear Error Register
F.F.0 on display and
readout by "Reset Error
Register" (W2 C150)
command using
.MAP110 or by power-
cycle.
Clear Error Register
F.F.0 on display and
readout by "Reset Error
Register" (W2 C150)
command using
.MAP110 or by power-
cycle.
77/84
Related
event
log #
N/A
N/A
N/A
© Landis+Gyr

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents