Revision history
Version Date
a
30.06.2012
b
30.6.2012
c
25.07.2012
d
17.08.2012
e
11.02.2013
© Landis+Gyr
Comments
Combined User Manuals D000028872 E230 ZxR100xC (version e,
issue 1.32) and D000030166 E230 ZMR100xR (version e, issue
1.32).
Section 2.4.7 Temperature values: Corrected maximum storage
temperature (+70°C).
Section 4.1.1 Meter construction: Added extra extended terminal
cover.
Section 6.6.1 Tariff control (ZMR100xR only): Deleted Status signal.
Section 6.9.1 Manual setting of date/time/ID: Added Id2.1 and Id2.2.
Section 6.15 IEC formatted commands: Updated command list.
Figure 13. Drilling diagram for fixing screws: Added 180 mm short
fixing.
Changed company name from "Landis+Gyr (Europe AG) to
"Landis+Gyr AG".
Other minor formatting and wording changes.
Minor formatting changes.
Corrected pulse output standard (IEC 62053-31).
Section 2.4.10 Output values: Deleted "no measurement of load
curve" from the description of pulse output r53.
Section 1 About this document: second restriction added.
Section 2.1 Functional overview: measuring technology updated and
RS485 interface added.
Section 2.3.2 E230 ZMR1x0AR/CR: RS485 interface added.
Section 2.4.6 Power consumption: power consumption data corrected.
Section 2.4.10 Output values: RS485 interface added.
Section 3.1 Safety information: safety concept updated and all notes,
cautions and warnings reformatted.
Section 4.2.5 Multi-tariff version with one pulse input, one relay output
and RS485 interface: new diagram added.
Section 4.2.6 Multi-tariff version with four pulse inputs and RS485
interface: new diagram added.
Section 6.1 Customer display: figures redrawn and rate indication
triangles added to list.
Section 6.1.1 Display cycle options: previous billing added.
Section 6.1.2 Example displays: RST replaced by L1, L2 and L3.
OBIS codes for summation, DC field, terminal tamper and meter case
tamper added.
Section 6.1.4 Meter powered with zero energy being consumed (anti-
creep mode): expanded information about energy direction and phase
indicators.
Section 6.1.6 Rate registers: advanced Rate and Relay indication
mode added.
Section 6.3 Push button operation: using the MD button to reset
alarms added.
Section 6.4.6 Alert notification: alert notification lists added.
Section 6.5 No power read (optional fitting): inductive loop deleted.
Section 6.7.4 Reset of maximum demand: MD register reset
procedure updated.
Section 6.8 Billing (stored values) (ZMR100xR only): new section
added.
Section 6.8.1 Unit suppression: new section added.
D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual