Technical Details; Measuring Accuracy; Rtc (Real Time Clock) Accuracy (Zmr100Xr Only); Voltage Values - Landis+Gyr E230 User Manual

Residential electricity meter
Table of Contents

Advertisement

Introduction
2.4

Technical details

2.4.1

Measuring accuracy

2.4.2

RTC (Real Time Clock) accuracy (ZMR100xR only)

2.4.3

Voltage values

2.4.4

Current values

D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual
Active Energy
Reactive Energy (Optional)
Active Power (Instantaneous)
Reactive Power (Instantaneous)
VRMS (Instantaneous)
IRMS (Instantaneous) at 0.25 A
IRMS (Instantaneous) at 8.0 A
IRMS (Instantaneous) at 100.0 A
Frequency
Power Factor
Crystal (internal to RTC)
Accuracy after calibration
Temperature Drift
Rated Voltage (U
)
n
3 x 230/400 V (3 x 120/200 V) 3 x 230 V
Nominal Value
3 x 220/380 V to 3 x 240/415 V
Operating Range
(3 x 110/190 V to 3 x 240/415 V)
0.8 to 1.15 U
Tolerance
MID Reference Current (I
Maximum Current (I
max
Starting Current
In accordance with MID Class B
In accordance with MID Class A
Maximum Measuring Range
Load Capacity
Measurements
Short Circuit < 10mS
Class B or A MID/IEC class 1 or 2
Class 2 or 3 IEC
± 10%
± 10%
± 2%
± 2.5%
± 0.8%
± 1.0%
± 2.0% at a resolution of 0.1 Hz
± 2.5%
32768 Hz ± 8 ppm max
± 3 ppm at 25°C
± 5 ppm / °C (-40°C...-15°C)
± 3 ppm / °C (-15°C...+60°C)
± 5 ppm / °C (+60°C...+70°C)
n
Configurable: 5, 10, 15 or 20 A
)
ref
125 A (Brass Terminals)
)
100 A (Steel Terminals)
0.4% I
ref
0.5% I
ref
Approx. 15 mA to 125 A
125 A
10,000 A (standard 30 x I