Landis+Gyr E230 User Manual page 76

Residential electricity meter
Table of Contents

Advertisement

76/84
Display
Description
00040000
Date Time
invalid (TOU
meters only).
00020000
Error accessing
EEPROM.
00010000
UNUSED
00008000
Failed
checksum when
restoring
registers from
EEPROM. (No
backup of
registers
available.)
© Landis+Gyr
If error is persistent
Billing based on energy
registers after the error
occurrence is not reliable
and may be subject to
discrepancies and
incorrect time-based
tariff switching. Billing
Profile (stored values)
will not be created
following this event type
and therefore Load
Profile data may also be
compromised. Maximum
Demand functions
independently of this
error type and is not
affected. Battery
Operating Time
functionality will no
longer be reliable once
this error bit is set.
Meter operation may be
compromised. Billing
based on energy
registers after the error
occurrence is not
reliable.
Meter operation may be
compromised. Billing
based on energy
registers after the error
occurrence is not
reliable. Error will only
occur during the power-
up sequence.
D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual
If error is transitional
Clear Error Register
F.F.0 on display and
readout by "Reset Error
Register" (W2 C150)
command using
.MAP110 or wait for the
error to be cleared
automatically after RTC
correction.
Clear Error Register
F.F.0 on display and
readout by "Reset Error
Register" (W2 C150)
command using
.MAP110 or by power-
cycle.
Clear Error Register
F.F.0 on display and
readout by "Reset Error
Register" (W2 C150)
command using
.MAP110 or by power-
cycle.
Error handling
Related
event
log #
66
N/A
N/A

Hide quick links:

Advertisement

Table of Contents
loading