Code
FTP Management
20
FTP hookup fail
21
FTP login fail
22
FTP 'type' fail
23
FTP 'cwd' fail
24
FTP data connection fail
25
FTP 'nlst' fail
26
FTP xfer command fail
27
FTP found no filename
28
FTP local file read/write fail
29
FTP socket fail
30
FTP completion error
31
FTP xfer timed out
_IGETFW
40
File in use, cannot download
41
Starting immediate update...
42
Complete
43
Downgrade disallowed
_IUPDFW
50
New firmware file not found
51
New firmware file corrupt
52
New firmware file failure
53
Upgrade admin file error
54
Upgrade status file error
_IGETFILE
60
Can't overwrite protected file
_IUPDCFG
70
Can't use reserved file
Chapter 6 • AT unsolicited response codes
70
3500834-0001 Revision C
Text
Connection to FTP server failed. Problem could be server
unreachable or specified IP address or server name invalid, or
connectivity failure.
FTP username or password incorrect
Could not establish "binary" mode.
Could not change to working directory on FTP server.
Could not establish an FTP data connection with the server.
Could not get list of files in current FTP server directory. Directory
may be empty.
Could not initiate data transfer on an established connection. May
be caused if filename not found.
Could not find a filename in the current server directory.
Error while writing downloaded file to UT flash or reading upload file
data.
Error while reading or writing FTP data socket.
Error while closing the current FTP connection.
FTP client timed out waiting for socket ready (read or write), e.g. due
to loss of connectivity during transfer.
The file to be downloaded is the same (by name) as the image
currently in use.
Normal success. File downloaded successfully, now starting
immediate update.
File listed in the response successfully downloaded to the UT
Downgrade to lower release blocked to protect hardware
Could not find filename specified in upgraded control file
Firmware file failed checksum test.
The new firmware failed to run or failed to acquire the network and
the unit fell back to the old release.
Problem with local file manipulation during upgrade process
Problem with local file manipulation during upgrade process
File specified in AT command was 'config.txt', 'config.chk',
'config_bk.txt', 'config_bk.chk'
Attempt to use one of protected config files as the new config.txt
file.