Insert the positive lead into the positive terminal jack and tighten the screw. Then
connect the negative lead into the negative terminal jack and tighten the screw (see
Figure
Install Ethernet cable and power wires through fittings
The Hughes 9502 has two standard bulkhead fittings. One fitting is for the power
wires and the other fitting is for the Ethernet cable.
feed the Ethernet connector/cable through the fitting. Once the cable is passed
through, you must then tighten the clamp nuts on the outside to ensure a positive
seal on the cable.
Figure 36: Connecting power leads
36).
Important Note:
•
Ensure the power source is turned off before connecting the power leads
to the 9502
•
Ensure that the screws are tightened to where the power leads cannot fall
out
1. Apply sealant (as required) to power wires and Ethernet cable
2. Slide cable/wires through fitting
3. Pull enough cable to mate to equipment
4. Tighten outer cinch nut to cable/wires
Figure 37
on page 56 how to
Chapter 4 • Installation instructions
3500834-0001 Revision C
55